SWITCH HYSTERESIS. UNITS:ms This defines the +/- hysteresis band around parameter 197. For example if par. 197 is 85 Hz, and par 198 is 5Hz, the switching will take place at 90Hz when the spindle is speeding up, and at 80 Hz when the spindle is slowing down.