Haas Alarm: 235 – SPINDLE Z FAULT

Haas Alarm: 235 SPINDLE Z FAULT – Encoder marker pulse count failure. This alarm usually indicates that the encoder mounted on the spindle has been damaged and encoder position data is unreliable. Loose encoder connectors at P1-P4 can also cause this.