Haas Parameter 279 – X MAX 3rd DERIV

X MAX 3rd DERIV This parameter supports S-curve. It is initialized to 250000000 and can be altered as needed. In order to ensure the desired effect, the minimum value that the control will use is:11700* ACCELERATION / ACC / DEC T CONSTIf the parameter is set to a lower value, the control will instead use the value computed using the above formula.