Haas Parameter 295 – SHTL SETTLE TIME

SHTL SETTLE TIME This is for the air driven shuttle (used on the VR series mills). This parameter allows settling time for the shuttle after it has moved toward the spindle and before a tool change is performed. It should be set to approximately half a second (500) on all mills with the Air Driven Shuttle. This may vary. All other mills can be set to 0 as they are unaffected by it.